This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Temperature Calibration Laboratory
The temperature laboratory has the capacity to perform calibrations by comparing the following instruments:
Relative Humidity Meters – Range of 10% to 93% with reference temperature between -40ºC to + 180ºC;
Temperature Gauges with Thermocouple Sensor – Range from -40ºC to + 180ºC;
Temperature Meters with Resistance Sensor and other Sensors – Range from -40ºC to + 180ºC;
Thermal Chambers:
- Control Temperature Deviation – Range from -200ºC to + 370ºC;
- Stability and Uniformity Study – Range from -200ºC to + 370ºC;
Climatic Chambers:
- Control Temperature Deviation – Range from -200ºC to + 370ºC;
- Stability and Uniformity Study – Range from -200ºC to + 370ºC;
- Control Relative Humidity Deviation – Range of 10% to 93% with reference temperature between -40ºC to + 180ºC;
Voltage, Current and Resistance Calibration Laboratory
Ability to perform calibrations on:
Battery Analyzer
- Voltage: 2 V to 6 V;
- Current: 50 mA up to 10 A;
Voltage Generators
- AC voltage (15 Hz to 50 kHz): 12 mV to 700 V;
- DC voltage: 10 mV up to 950 V;
Resistances:
- Resistance: 1Ω to 1000 MΩ;
DC current
- Current: 1 uA to 10 A;
AC current
- AC current (60 Hz to 1 kHz): 1 uA to 10 A;
Frequency
- Frequency: 15 Hz to 225 MHz;
EMC Calibration Laboratory (Electromagnetic Compatibility)
Ability to perform calibrations on:
Electrostatic Discharge Generator
- Discharge via Air – 2 kV / 4 kV / 8 kV / 15 kV;
- Contact Discharge (Peak Current / 30 ns and 60 ns) – 2 kV / 4 kV / 6 kV / 8 KV;
Voltage Reduction, Interruption and Variation Generator
- Voltage amplitude at 60 Hz: Level from 0% to 100%;
- Duration from 8 ms to 5000 ms;
Surge Generator
- Peak Voltage Amplitude with open circuit: 0V to 7000V;
- Time of Rise of Voltage and Current Pulses: 0.7 us to 60 us;
- Duration of Voltage and Current Pulses: 10 us up to 35 us;
- Residual Voltage between Application Lines: 0 to 7000V;
- Short-Circuit Current (Peak): 250 A to 5000 A;
- Pulse Repetition Rate: Up to 60 s.
Fast Electric Transient Generator
- Peak Pulse Voltage: 250 V to 4000 V:
- Pulse Rise Time: 0.7 us to 60 us;
- Pulse Duration Time: 30 ns to 120 ns;
- Pulse Repetition Rate: 5 kHz to 100 kHz;
- BURST duration: 0.75 ms up to 15 ms;
- BURST period: 0 ms to 500 ms;